Do not allow anyone who has not read these instructions to assemble, light, adjust or operate the heater. It is not intended as a substitute for the actual owners. Reddy heaters typically use multiple fuels and an air pump to quickly heat large sheds and workshops. The pump has a sort of pressure regulator, more like a simple screw and spring pressure relief, that determines how much fuel is blown in and that regulator can get plugged up causing the air pump to deliver too much fuel causing a slight to.
We will look for a gauge and make the proper adjustments and then go from there. Always remember that kerosene is flammable, electrical parts. Place instructions in a safe place for future reference. Sad as it is, the torpedo heaters of today are throw away units. Jul 17, 2017 do not try to increase the pressure on your reddy heater past manufacturer specifications, or the heater will stop working.
It is not required to have the ha1180 air pressure gauge to set you heater to the proper running pressure, this can be done by increasing the air pump pressure until the nose cone of the heater in a nice glowing orange color and no harsh fumes are being presented by the heater. It provides efficient zone heating about 380 square feet. Nov 30, 2010 this will show you how to adjust the pump pressure on your kerosene forced air heater or as they are commonly called, a torpedo heater. Troubleshooting and how to do in this article, we will go through how a kerosene heater works, what are the common problems, and how to deal with them. Ha1180 kerosene heater air pressure guage desa reddy mr. The first symptom that there is a problem is that the heater will run for 5 seconds and shut down. Refer to the users manual for instructions on cleaning these components. Dec 07, 2014 sad as it is, the torpedo heaters of today are throw away units.
Jul 17, 2017 check for fuel problems if the motor runs, but the heater wont ignite, or if you spot smoke or smell an odor coming from the unit. M16545 wfree pp217 desa filter cover and pump adjustment kit reddy 040026. The heatstream 125,000 btu dieselkerosene forced air torpedo heater is an ideal space heating solution for spaces up to 3,100 sq. In the girlz n the barn, taryl shows you what to look for when repairing a torpedo heater. Know how to setup pump pressure, clear fuel source, repair rotors, check faulty thermostat. Kerosene to diesel portable heater conversion i have a reddy heater, not sure of model, but is 35,000 btu, and cannot tell any difference in burning kerosene versus low sulfur diesel. The only way to correct this problem is to set the pump pressure to desas recommended pressure specification. Dec 11, 2016 if your torpedo heater keeps shutting off, or your torpedo heater wont fire then you need to watch my video, how to fix a torpedo heater one of the cheapest and easiest fixes that you will have. Kerosene forced air heater not for diesel usage r350 heaters heat up to 8,225 sq. Kerosene heater troubleshooting home guides sf gate. If your reddy heater does not put out enough heat, you most likely have a problem with the pressure in the air pump. When used with thermostat, heater may start anytime.
A heater may still light with insufficient soaking, however, air bubbles develop in the capillaries of the wick, preventing the proper flow of kerosene. Reddy heater kerosene heater m19630 fuel filter 100,000 to 250,000 btu old style. Product title dynaglo rmc55r7b 10,000 btu indoor kerosene radiant heater average rating. This is accomplished by air and fuel being mixed and sprayed through the nozzle. It utilizes heatstreams tried and true torpedo heater design, honed over the last 6 decades. This video will describe how to set the pump pressure on a kerosene forced air heater from pinnacle climate technologies master, protemp, remington, stanley international. Save reddy heater parts to get email alerts and updates on your ebay feed. Water in kerosene causing dwindling and poor performance.
Kerosene heater trouble shooting guide this trouble shooting guide can be used as a quick reference to aid you in detecting the causes and performing simple maintenancerepair procedures. I believe we have good atomization from the way it looks with the cover off. Start by inspecting the fuel tank for water, which forms globules if present. The one on the right is slotted for adjustment of pressure. Master, reddy, remington, torpedo and salamander type kerosene forced air heaters. How to fix a torpedo heaterone of the cheapest and. Or possibly, the heater will run fine with the top cover removed but when the cover is replaced the heater shuts down. M16545 wfree pp217 desa filter and pump kit reddy 040026.
Heaters with hot surface ignitor technology are extremely critical to pump pressure. Each nozzle is made specifically for a certain heater so make sure to match the nozzle with the model number of your heater. There should be two small plastic covers, looking directly at the back, the one on the left can be removed and a pressure gauge installed. How to fix a torpedo heaterone of the cheapest and easiest fixes. Even a loss of onequarter pound per square inch or psi in pressure can cause a 30 percent loss in heating capacity. Troubleshooting tips for reddy spark plug type heaters. Apr 12, 2019 fix no spark was the issue with this reddy heater. Blowdry and replace the filter and see if the issue has been resolved. Heater ts75kt operating instructions and owners manual online. Clean the tank completely and refuel with the recommended fuel oil, kerosene or diesel if you spot water. Dec 14, 2018 a kerosene heater can help keep you warm during a power outage. Find great deals on ebay for reddy heater parts and reddy heater 170t parts. A lack of vigilance while using the heater, such as running it over night or leaving it unattended.
Ive got a 150,000 btu reddy heater that still looks almost new, but was retired to the junk shed several years ago. Check and adjust the pump pressure to the manufacturers specifications listed in the users manual. Installing kerosene heater wicks generic for unpinned wicks. Apr 15, 2019 most ready heaters have a fuel pressure setting on the back of the heater near the fan.
Oct 07, 20 on most of these types of heaters there is a small rotary vane type air pump that is used to regulate and atomize the fuel flow. Diesel is dirty fuel and will crud up your heater faster. When moving or storing heater, keep heater in a level position or fuel spillage may occur. I am usually in the office from 8am til 5pm chicago time in the winter oct thru march.
Kerosene to diesel portable heater conversion tool talk. It is great alternative heating source and excellent emergency heating source in events of power failure no electricity is required. Be sure to soak the wick in the down position in a full tank of fuel for at least 60 minutes. Diesel burns surprisingly well in my 23,000 btu kerosun brand kerosene heater. Verify if there is any air leaks from reddy heater. Heater flame sensor kit for all kerosene forced air heaters. If operating properly, the pump should produce more pressure than is required to operate the heater. Ive got a 150,000 btu reddyheater that still looks almost new, but was retired to the junk shed several years ago. How to clean a kerosene heater wick home guides sf gate. On most of these types of heaters there is a small rotary vane type air pump that is used to regulate and atomize the fuel flow. Never adjust the pressure settings on a heater while its running. The newest style radiant kerosene heater 10,000 btu is safe and easy to use and economical to operate. We have the reddy parts you need, with fast shipping and great prices. If your torpedo heater keeps shutting off, or your torpedo heater wont fire then you need to watch my video, how to fix a torpedo heater one of the cheapest and easiest fixes that you will have.
In the case of kerosenebased reddy heaters, you must use grade 1k kerosene as a fuel source at all times. Find great deals on ebay for reddy kerosene heaters. The room must be well ventilated with a window or door cracked. Ts125kt, ts175kt, ts210kt, buddypro air ts75kt, buddypro air ts125kt, buddypro air. The other hole longer projection has a screw with a hole which adjusts a ball and spring relief valve assembly. Dec 31, 2010 thank you tom, i accept your ideas and have printed off the reddy heater info.
Wait until the heater completely cools before placing soapy water on any part of the unit to test for leaks, or you may create steam that will scald your skin. Most ready heaters have a fuel pressure setting on the back of the heater near the fan. Yes, you can get parts for them, but the cost of just a few parts will be very close to the price of a brand new unit. I could detect no difference in flame height or heat output and no odors. The pump pressure determines the heat output of the heater. Kerosenediesel forced air torpedo heaters faq master. Reddy heater r110 forced air kerosene heater parts quickly shipped mondayfriday. Kerosene heaters can be used indoors with a few safety measures. A kerosene heater can be handy in the home when the power goes out, or to save on electric and gas bills.
If you have a question about our parts or parts in general feel free to call. Dieselkerosene forced air torpedo heater 125,000 btu. Kerosene heaters general types, how they work, recommendations for some good ones and those i would avoid. For kerosene heater parts and accessories, think jacks. Heater breakdowns desa master, reddy, remington, sears. Please be advised that because of the additives contained in diesel fuel, additional ventilation will be required to disperse the added contaminants produced. Thank you tom, i accept your ideas and have printed off the reddy heater info. Desa kerosene forced air service manual for spark plug.
Desa reddy kerosene heater fuel nozzle pp235 new part. The purpose of the fuel nozzle is to atomize the fuel to prepare it for combustion. Diesel will burn a little dirtier so you will have more fumesodor. The ignitor plug may not last quite as long or foul out a little sooner with diesel talking maybe 23 seasons instead of 45 remember, with either fuel, they do produce toxic fumes so use them in a ventilated area only. This item ha1180 kerosene heater air pressure guage desa reddy mr. Most of them are in line above the fuel tank, some are in line inside the fuel tank. Most are made to burn either so it should work fine. Dieselkerosene forced air torpedo heater 125,000 btu heat. A dirty fuel filter or nozzle can obstruct the flow of fuel to the spark plug. The wick in a kerosene heater is as vital to its correct operation as the kerosene itself. Troubleshooting the hsi hot surface ignitor or glowbar type heater.
Adjusting pump pressure on your forced air heater youtube. A kerosene heater can help keep you warm during a power outage. Locate heater on a stable and level surface if heater is hot or running or a. Both can be accessed by removing rectangular cover plate on left side of heater. Carefully adjust the screw until the gauge is reading the pressure level that is specified on the heaters label. The price for this product was dramatically reduced than other sites i researched, instead of much more compared to similar product. Use caution and common sense when working on a heater. Flame spreader heaters and lamps a century of excellence. Lots of good tips and things to check and go through when pulling out that old heater. There were some droplets on the floor from it quitting. A friend that works at the local fuel coop told me that diesel may reduce the life of the wick but so far i cant tell any difference. Remove the fuel filter and clean it with fresh fuel if the heater wont start and produces smoke or odors. This will show you how to adjust the pump pressure on your kerosene forced air heater or as they are commonly called, a torpedo heater. This type of heater is portable, so it is easy to move from room to room as needed.
437 328 1265 1473 1110 959 457 528 1133 476 682 58 195 1052 1046 884 1163 49 760 1269 264 413 945 616 138 340 1278 55 420 1171 1231 923